Configuration
8200SHB0199
7-77
7.8 Code table for Standard” series
How to read the code table:
Column Abbreviation Meaning
Code C013 Code C013
-
The parameter of the code can be different in PAR1 and PAR2.
-
The parameter value is accepted immediately (ONLINE).
C009*
-
The parameter value of the code is always the same in PAR1 and PAR2, but is
always displayed in PAR1.
C001¤
-
The parameter value of the code will be accepted after pressing SH+ PRG.
[C002]
-
The parameter value of the code will be accepted after pressing SH+ PRG but
only, if the controller is inhibited.
C010
-
Parameter value of the code will only be displayed in [Hz], if C500 = 2000 and
C501 = 10 (factory setting). See chapter 7.6.3.
Name
820X
Name of the code.
Unit-specific setting possibilities (here for 820X).
Without unit designation the code is valid for all unit types.
Lenze Factory setting of the code
* The column ”Important” contains further information
Choice 1{1%}99Min. value {Steps/Unit} Max. value
Info - Meaning of the code
IMPORTANT - Additional, important explanation of the code
Code Name Possible settings IMPORTANT
C
o
d
e
N
a
m
e
Lenze Choice Info
I
M
P
O
R
T
A
N
T
C001¤ Operating mode -0- -0- Setpoint selection via term. 8
Control via terminals
Parameter setting via 8201BB
-1- Setpoint selection via 8201BB or
LECOM
Control via terminals
Parameter setting via 8201BB
-2- Setpoint selection via term. 8
Control via terminals
Parameter setting via LECOM
-3- Setpoint selection via LECOM
Control via LECOM
Parameter setting via LECOM
Page 7-9,
7-42
[C002]* Parameter set -0- Function executed
-1- Overwrite PAR1 with factory setting
-2- Overwrite PAR2 with factory setting
-3- Overwrite PAR1 and PAR2 with the
data of the operating module
-4- Overwrite PAR1 with the data of the
operating module
-5- Overwrite PAR2 with the data of the
operating module
-6- Transmit PAR1 and PAR2 to the
operating module
Page 7-10
C004¤ Switch-on display -0- -0- Field frequency f
d
-1- Unit load
-2- Motor current
Page 7-62