Installation
8200SHB0199
4-35
4.2.7.4 Connection plan 820X
L1
U
V
W
+UG
-UG
M
3~
PE
RB1 RB2
+UG
-UG
K10
K10
RB
L1
PE
8201... 8204
Z3
N
K10
-X1
N/L2
F1 F2*
PE
Z1
PE
PE
PE
PE
PE
PE
Z
Z4
2
ϑ
R
B
K10*
FIG 4-20 820X power connections
F1, F2* Fuses, F2*only for supply with 2AC / PE / 190 - 260 V
K10, K10* Mains contactor, K10*only for supply with 2AC / PE / 190 - 260 V
Z1 Mains choke, see Accessories (not required when using mains filters)
8204 operation only with assigned mains choke/mains filter
Z2 Motor filter/sine filter, see Accessories
Z3 Brake chopper/brake module, see Accessories
Z4 RFI filter/mains filter (symmetrically designed filters for L1/N (L2)
RB Brake resistor, see Accessories
J
RB
Temperature monitoring brake resistor
X1 Terminal strip in control cabinet