parameters via the
operating module.
Function Suppression of idling oscillations when:
-
a drive does not match, i.e. rated controller power - motor
e.g. operation with high chopper frequency and the related power derating,
-
operation of higher-pole motors,
-
operation of special motors,
-
having a resonance phenomenon in the drive set.
Adjustment 1.Approach the area with speed oscillations.
2.Reduce the oscillation by changing C079 step by step.
- Indicators for smooth running can be a uniform motor current or the reduction of the
mechanical vibrations in the bearing seat.
Important
-
Parameter transfer from C079 not possible via keypad.
-
Compensate the resonances in speed controlled operation via the parameters of the controller.