Technical Data
8200SHB0199
3-13
150 % overload Type 8225 8226 8227
Order No. EVF8225-E EVF8226-E EVF8227-E
Variant “HVAC” Type 8225-V020 8226-V020 8227-V020
Order No. EVF8225-E-V020 EVF8226-E-V020 EVF8227-E-V020
Power derating [%/K]
[%/m]
40 C<T
V
<50C: 2.5 %/K
1000 m a.m.s.l. h $ 4000 m a.m.s.l.: 5 %/1000 m
Field
frequency
Digital setpoint selection Accuracy á0.05 Hz
Analog setpoint selection
Linearity á0.5 %(max. selected signal level: 5 V or 10 V)
Temperature
sensitivity
0 ¡ 40 C: +0.4 %
Offset á0%
Weight m[kg] 36.5 59 59
Printed in bold Data for the operation with factory setting and a chopper frequency of 8 kHz.
1)
This power can be additionally obtained when operating a matching motor
2)
The currents apply to a periodical load cycle with 1 minute overcurrent with the current mentioned here and
2 minutes base load with 75 % I
rx
.
3)
With mains choke/mains filter: max. output voltage = approx. 96 % of the mains voltage
4)
Only with variant “HVAC”
5)
Must only be operated with C144 = -1- (automatic chopper frequency derating at J
max
=+5C). Ensure not to
exceed the currents.
* Chopper frequency of the inverter
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com