Parameter Name / value range / [default seng] Info
0x2631:017
(P400.17)
Funcon list: Acvate network setpoint
(Funcon list: Setp: Network)
•
From version 02.01
•
For further possible sengs, see parameter
0x2631:001 (P400.01). ^ 532
Assignment of a trigger for the "Acvate network setpoint" funcon.
Trigger = TRUE: the network is used as setpoint source (if the trigger
assigned has the highest setpoint priority).
Trigger = FALSE: no acon / deacvate funcon again.
0 Not connected
116 Network setpoint acve (from version 02.00) TRUE if a change-over to network setpoint is requested via bit 6 of the
AC drive control word0x400B:001 (P592.01). Otherwise FALSE.
Notes:
•
Set this selecon if the network setpoint is to be acvated via bit 6 of
the AC drive control word.
•
The AC drive control word can be used with any communicaon pro-
tocol.
4AC Drive Prole ^ 248
0x6402 Motor type
•
From version 02.00
AC motor type
•
Motor Data Object (0x28) - instance aribute 3
3 PM synchronous
7 Squirrel cage inducon
Conguring the network
EtherNet/IP
Objects
330