Address Designaon Default seng Category Data type Factor A M
0x4030:001 ...
0x4030:016
(P830.01 ... 16)
Sequence 1: Step 1 ... Step 16 Skip step [0] general I8 1 P -
0x4031
(P831.00)
Number of cycles sequence 1 1 general U16 1 P -
0x4032:001 ...
0x4032:016
(P835.01 ... 16)
Sequence 2: Step 1 ... Step 16 Skip step [0] general I8 1 P -
0x4033
(P836.00)
Number of cycles sequence 2 1 general U16 1 P -
0x4034:001 ...
0x4034:016
(P840.01 ... 16)
Sequence 3: Step 1 ... Step 16 Skip step [0] general I8 1 P -
0x4035
(P841.00)
Number of cycles sequence 3 1 general U16 1 P -
0x4036:001 ...
0x4036:016
(P845.01 ... 16)
Sequence 4: Step 1 ... Step 16 Skip step [0] general I8 1 P -
0x4037
(P846.00)
Number of cycles sequence 4 1 general U16 1 P -
0x4038:001 ...
0x4038:016
(P850.01 ... 16)
Sequence 5: Step 1 ... Step 16 Skip step [0] general I8 1 P -
0x4039
(P851.00)
Number of cycles sequence 5 1 general U16 1 P -
0x403A:001 ...
0x403A:016
(P855.01 ... 16)
Sequence 6: Step 1 ... Step 16 Skip step [0] general I8 1 P -
0x403B
(P856.00)
Number of cycles sequence 6 1 general U16 1 P -
0x403C:001 ...
0x403C:016
(P860.01 ... 16)
Sequence 7: Step 1 ... Step 16 Skip step [0] general I8 1 P -
0x403D
(P861.00)
Number of cycles sequence 7 1 general U16 1 P -
0x403E:001 ...
0x403E:016
(P865.01 ... 16)
Sequence 8: Step 1 ... Step 16 Skip step [0] general I8 1 P -
0x403F
(P866.00)
Number of cycles sequence 8 1 general U16 1 P -
0x4040
(P820.00)
Start of sequence mode Restart sequencer [0] general U8 1 P -
0x4041:001 ...
0x4041:032
(P750.01 ... 32)
Parameter change-over: Parameter 1 ... Parameter
32
0x00000000 general IDX 1 PH -
0x4042:001 ...
0x4042:032
(P751.01 ... 32)
Parameter value set 1: Value of parameter 1 ... Value
of parameter 32
0 general I32 1 P -
0x4043:001 ...
0x4043:032
(P752.01 ... 32)
Parameter value set 2: Value of parameter 1 ... Value
of parameter 32
0 general I32 1 P -
0x4044:001 ...
0x4044:032
(P753.01 ... 32)
Parameter value set 3: Value of parameter 1 ... Value
of parameter 32
0 general I32 1 P -
0x4045:001 ...
0x4045:032
(P754.01 ... 32)
Parameter value set 4: Value of parameter 1 ... Value
of parameter 32
0 general I32 1 P -
0x4046
(P755.00)
Acvaon of parameter set Via command (disable
required) [0]
general U8 1 P -
0x4047:001
(P756.01)
Parameter change-over error message: Status - (Read only) general U16 1 - -
* Default seng depending on the size. Firmware version 05.00.00.00
Appendix
Parameter aribute list