7.4 Interface
The following interfaces are available for controlling a technology applicaon:
•
Fieldbus in
terface [0]
•
System bus interface [1]
The
selecon of the interface is performed in »EASY Starter«:
•
Select the Sengs tab, then the Technology applicaon parameter dialog.
When changing the parameter, the inverter must be inhibited.
The switch-over eects a switch in the control and status words. Depending on the technology
applicaon chosen, the bits of the respecve control words and status words are already pre-
assigned.
Assignment of control words and status words:
4Control signals ^ 108
4Status signals ^ 109
The following illustraon shows the basic signal ow within the technology applicaon and
the change-over mechanism of the parameter Interface selecon. 40x4001
Control signals
Interface switch
0x4001:000
Control word 00
Control word 01
Control word 02
Control word 03
Control word 04
Control word 05
Control word 06
Control word 07
Control word 00
Control word 01
Control word 02
Control word 03
Control word 04
Control word 05
Control word 06
Control word 07
Systembus
Fieldbus
Status word 00
Status word 01
Status word 02
Status word 03
Status word 04
Status word 05
Status word 06
Status word 07
Status word 00
Status word 01
Status word 02
Status word 03
Status word 04
Status word 05
Status word 06
Status word 07
Systembus
Fieldbus
Technologie applikation
Winder dancer
Status signals
Set diameter
Set velocity (line velocity)
Set tension
Tens controller
influence
Actual tension
Free control word 06
Free control word 07
Control signals
Status signals limiter
Actual velocity
Actual position
Error code
Actual diameter
Monitoring signal 1
Monitoring signal 2
Status signals
Fig. 42: Signal ow of the technology applicaon
Parameter
Address Name / seng range / [default seng] Info
0x4001 Interface selecon
Selecng the interface determines the interface that receives the signals.
0 Fieldbus network Control of the applicaon via the
eldbus.
1 Systembus network Acvaon of the applicaon via the system bus.
Conguring the "Winder Dancer" TA
In
terface
107