EasyManua.ls Logo

Lenze i950

Lenze i950
496 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16.1.6.1 Not ready to switch on
This is the device state of the inverter directly aer switching on the supply voltage.
In this de
vice status, the device is inialised.
Communicaon is not possible yet.
The in
verter cannot be parameterised yet and no device commands can be carried out yet.
The motor brake, if available, is closed.
Operaon is inhibited.
Mains on
Quick stop active
Switch-on inhibited
Fault
Fault reaction
active
Operation enabled
Switched on
Not ready
to switch on
Ready to switch on
1 From all states
2 Power secon inhibited (pulse inhibit)
3 Power secon enabled
Bit paern in the CiA 402 status word (0x6041)
Bit 15 ... 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Reserved
(specic)
Warning
acve
Operaon
inhibited
Quick stop
acve
DC bus ready
f
or operaon
Fault acve Operaon
enabled
Switched on Ready to
switch on
X X 0 X X 0 0 0 0
X = state is not relevant
Conguring the network
De
vice prole CiA 402
Device states
324