7.3.4 Source for set dancer posion
The setpoint posion of the dancer is dened via the eldbus interface or a parameter.
1
0
1
0
0x5052:178
0x4001:000
0x5052:177
0x5050:023
0x5052:179
Dancer set position
Fieldbus
Systembus
Interface switch
Enable internal dancer set pos
In: dancer set position
Valid dancer set pos
Fig. 39: Acvaon of the parameter for the internal dancer conguraon
Relevant parameters of other funcons
Address Designaon Default seng Seng range
0x4001 Interface
selecon Fieldbus network [0] Selecon list
0x5050:023 Set dancer posion (input value) 0.00 % -100.00 ... 100.00 %
0x5052:177 Source of dancer set posion External [0] Selecon list
0x5052:178 Dancer set posion 0.00 % -21474836.48 ... 21474836.47 %
0x5052:179 Eecce dancer set posion x.xx % (Read only)
7.3.5 Source for actual dancer posion
The signal for the current dancer posion is transmied via the eldbus interface or a sensor
c
onnected to the technology applicaon at analog input 1.
1
0
1
0
0x2DA4:005
0x4001:000
0x5020:023
0x5050:025
0x5052:189
Analog input 1
Fieldbus
Systembus
Interface switch
Source dancer actual position
Dancer actual position
Dancer actual position
filtered
PT1-Filter
Scaling
Fig. 40: Source of actual dancer posion
Relevant parameters of other funcons
Address Designaon Default seng Seng range
0x2DA4:005 Diagnoscs of analog input 1: Scaled percent value x.xx % (Read only)
0x4001 Interface selecon Fieldbus network [0] Selecon list
0x5020:023 Actual dancer posion source Analog input 1 [1] Selecon list
0x5050:025 Actual dancer posion (input value) 0.00 -21474836.48 ... 21474836.47
0x5052:189 Eecve actual dancer posion x.xx % (Read only)
Conguring the "Winder Dancer" TA
Sour
ce selecon for control signals
Source for actual dancer posion
105