7.10.2 Dancer limit
posion teach-in funcon
The teach funcon can be used to congure the reference values for the scaled signal of the
actual dancer posion during commissioning.
How to dene the upper and lower dancer end posion:
1.
Se
t the parameter Dancer limit posion source to 1. 40x5052:173
2.Move the dancer manually to the lower dancer end posion, such that the maximum mate-
rial length is bound up in the dancer.
This will generate a FALSE/TRUE/FALSE edge in bit 30 of the parameter Control signals.
40x5050:010 Bit 30
3.Move the dancer manually to the upper dancer end posion, such that the minimum mate-
rial length is bound up in the dancer.
This will generate a FALSE/TRUE/FALSE edge in bit 25 of the parameter Control signals.
40x5050:010 Bit 25
The current input values Dancer posion raw value ar
e permanently saved in the technol-
ogy applicaon. 40x5052:190
Relevant parameters of other funcons
Address Designaon Default seng Seng range
0x5052:169 Teached dancer upper limit posion - (Read only)
0x5052:170 Teached dancer lower limit posion - (Read only)
0x5052:173 Dancer limit posion source 0
0x5052:190 Dancer
posion raw value - (Read only)
Conguring the "Winder Dancer" TA
Dancer c
ontrol
Dancer limit posion teach-in funcon