EasyManua.ls Logo

Lenze i950

Lenze i950
496 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.4.3 Simulaon of the interface
The technology interface is operated via the following parameters:
Simulaon of control signals 40x5050:001 bit 0
... 7
Simulaon of status signals 40x5050:101 bit 0
Control signal simulaon
Bit Funcon
0 Acvates the
simulaon of the control signals.
The rst double word of the control words switches over to manual
operaon.
1 ... 7 Acvates the simulaon of the control signals. Selecng the bits triggers
switchover to manual operaon.
Status signal simulaon
Bit Funcon
0 Acvates the
simulaon of the status signals.
All status words are switched over to manual operaon.
The technology interface is operated via the following parameters:
Simulaon of control signals 0x5040:001 bit 0
... 7
Simulaon of status signals 0x5040:101 bit 0
Control signal simulaon
Bit Funcon
0 Acvates the
simulaon of the control signals.
The rst double word of the control words switches over to manual
operaon.
1 ... 7 Acvates the simulaon of the control signals. Selecng the bits triggers
switchover to manual operaon.
Status signal simulaon
Bit Funcon
0 Acvates the
simulaon of the status signals.
All status words are switched over to manual operaon.
0x5050:017
0x5050:016
0x5050:0 52
0x5050:0 42
0x5050:0 32
0x5050:012
0x5050:011
0x5050:010
0x5050: 01 Bit 01
0x5050:001:Bit 1
0x5050:001:Bit 7
0x5050:001 Bit 0
Status word 00
Status word 01
Status word 02
Status word 03
Status word 04
Status word 05
Status word 06
Status word 07
Fieldbus/Systembus
Status signals
Status signals limiter
Actual velocity
Actual position
Out: Actual diameter
Out: Monitoring signal 1
Out: Monitoring signal 2
Error code
Winder
dancer
Free control word 07
Free control word 06
In: Dancer a . positionct
In: Dancer trl. luence c inf
Dancer s positionet
In: Set velocity (line)
In:Set diameter
Control signals
Internal control
Internal control
Internal control
Internal control
Control word 07
Control word 06
Control word 05
Control word 04
Control word 03
Control word 02
Control word 01
Control word 00
Fieldbus/Systembus
Fig. 43: Signal ow in the simulaon of the technology applicaon
Conguring the "Winder Dancer" TA
In
terface
Simulaon of the interface
112

Table of Contents