7.3.6 Source for dancer control correcon value
The dancer control inuence evaluates the dancer control output mulplicavely. It can be
congured in two dierent ways:
1.
St
andard seng via the eldbus interface
2.
Via the in
ternal parameter Set dancer control inuence 40x5052:175
The actual dancer posion is given by the setpoint and the dancer control correcon value.
1
0
1
0
Set ancer trl influenced c
0x5052:175
Fieldbus
Systembus
Interface switch
0x4001:000
Enable internal dancer ctrl
influence 0x5052:174
In: Dancer control influence
0x5050:024
Valid dancer ctrl
influence 0x5052:176
Fig. 41: Source switching for the dancer control inuence
Relevant parameters of other funcons
Address Designaon Default seng Seng range
0x4001 Interface
selecon Fieldbus network [0] Selecon list
0x5050:024 Dancer control inuence (control word 5) 0.00 % 0.00 ... 21474836.47 %
0x5052:174 Source of dancer control inuence External [0] Selecon list
0x5052:175 Set dancer control inuence 0.00 % -21474836.48 ... 21474836.47 %
0x5052:176 Eecve dancer control inuence x.xx % (Read only)
Conguring the "Winder Dancer" TA
Sour
ce selecon for control signals
Source for dancer control correcon value
106