Address Name / seng range / [default seng] Info
0x5020:020 Line velocity source
0 External
1 Load encoder
3 Synchronized with master value
0x5021:152 System bus diagnoscs: Velocity (input value)
R
ead only
Speed conducvity
0x5050:023 Set dancer posion (input value)
-100.00 ... [0.00] ... 100.00 %
The value of the external dancer posion is specied in [%]. It has 2 deci-
mal posions.
0x5050:024 Dancer control inuence (control word 5)
0.00 ... [0.00] ... 21474836.47 %
The value of the external dancer control inuence can be congured
within a range of 0%-100%.
0x5051:007 Evaluaon line velocity - numerator
-2147483648.0000000000 ... [1.0000000000] ...
2147483647.0000000000
0x5051:008 Evaluaon line velocity - denominator
-2147483648.0000000000 ... [1.0000000000] ...
2147483647.0000000000
0x5051:009 Actual line velocity
Read only: x.xxxx mm/s
The parameter is resolved with 4 decimal posions. The parameter has
the unit [mm/s].
0x5051:012 Line velocity reference
0.0000 ... [1000.0000] ... 214748.3647 mm/s
0x5051:033 Eecve set speed
Read only: x.xx rev/s
0x5051:096 Actual diameter
Read only: x.xxxx mm
The parameter is resolved with 4 decimal posions. The parameter has
the unit [mm].
0x5052:174 Source of dancer control inuence
0 External Inuence of dancer control
1 Parameter Inuence of dancer control via parameter
0x5052:175 Set dancer control inuence
-21474836.48 ... [0.00] ... 21474836.47 %
0x5052:176 Eecve dancer control inuence
R
ead only: x.xx %
0x5052:177 Source of dancer set posion
0 External Setpoint posion of dancer via eldbus
1 Parameter Setpoint posion of dancer via parameter value
Conguring the "Winder Dancer" TA
Dancer c
ontrol
130