7.12 Idenfying moments of inera
Parameter
Address Name / seng range / [default seng] Info
0x5051:110 Actual moment of inera
R
ead only
The parameter is only shown.
0x5051:111 Constant moment of inera
1.0000000000 ... [1.0000000000] ...
2147483647.0000000000
The parameter has the unit [kgcm
2
].
0x5051:112 Max. moment of inera
1.0000000000 ... [10.0000000000] ...
2147483647.0000000000
0x5051:113 Moment of inera
idencaon - velocity lter me
0.001 ... [0.010] ... 10.000 s
0x5051:114 Moment of inera idencaon - torque lter me
0.001 ... [0.005] ... 10.000 s
0x5051:115 Moment of inera idencaon - max. velocity
1.00 ... [20.00] ... 100.00 %
0x5051:116 Moment of inera idencaon - max. torque
1.00 ... [20.00] ... 100.00 %
0x5051:117 Idenfy moment of inera
false Disabled Deacvated
true Enabled Acvated
0x5051:118 Measured moment of inera
R
ead only
0x606C Velocity actual value
R
ead only: rpm
Display of the actual velocity.
0x6077 Torque actual value
Read only: x.x %
Display of the current torque.
100 %
≡ Rated Motor Torque. 40x6076