7.3.1 Source for line speed
The line speed signal can be transmied from various sources in the technology applicaon.
When using the technology applicaon with another i950 product series inverter that deter-
mines the speed of the machine, the mas
ter value is transmied via the system bus. Line
velocity source 40x5020:020 Selecon [3]
In the technology applicaon, the line speed signal is scaled to [mm/s] with 4 decimal places.
If the posion unit of the master is not the unit [mm], the unit can be adapted via the numer-
ator-denominator evaluaon.
Numerator-denominator evaluaon:
•
Evaluaon line velocity - numerator 40x5051:007
•
Evaluaon line velocity - denominator 40x5051:008
Example:
The speed-determining drive is the master of a machine. The master operates with a rotary
measuring s
ystem and a feed constant of [360°/r]. The speed in [°/s] is transmied via the sys-
tem bus to the winder. A single output-end revoluon of the master conveys the material by
194.7787 [mm] per revoluon in the direcon of material ow. This distance corresponds to
the circumference of the feed roll or the measuring wheel. This results in a factor of 1:1.
Relaonship of numerator to the denominator
•
Evaluaon line velocity - numerator = 194.7787
[mm] (linear feed) 40x5051:007
•
Evaluaon line velocity - denominator = 360.0000 [°] (congured feed constant of master)
40x5051:008
If necessary, the line speed signal can be negated with a negave value via the parameter
Evaluaon line velocity - numerator. 40x5051:007
0x5021:152
1
0
3
1
0
0x50 :0B 011
0x4001:000
0x5020:020
0x5050:012
0x5051:009
Master velocity in
Actual velocity
Fieldbus
Systembus
Interface switch
Source line velocity
Reference line velocity
Actual line velocity
Fig. 36: Selecon of the source for the line speed
Relevant parameters of other funcons
Address Designaon Default seng Seng range
0x4001 Interface
selecon Fieldbus network [0] Selecon list
0x500B:011 Actual velocity - (Read only)
0x5020:020 Line velocity source External [0] Selecon list
0x5021:152 System bus diagnoscs: Velocity (input value) - (Read only)
0x5051:007 Evaluaon line velocity - numerator 1.0000000000 -2147483648.0000000000 ...
2147483647.0000000000
0x5051:008 Evaluaon line velocity - denominator 1.0000000000 -2147483648.0000000000 ...
2147483647.0000000000
0x5051:009 Actual line velocity x.xxxx mm/s (Read only)
Conguring the "Winder Dancer" TA
Sour
ce selecon for control signals
Source for line speed
103