7.3.1 Source for line speed
The line speed signal can be transmied from various sources in the technology applicaon.
When using the technology applicaon with another i950 product series inverter that deter-
mines the speed of the machine, the mas
ter value is transmied via the system bus. Line
velocity source 40x5020:020 Selecon [3]
In the technology applicaon, the line speed signal is scaled to [mm/s] with 4 decimal places.
If the posion unit of the master is not the unit [mm], the unit can be adapted via the numer-
ator-denominator evaluaon.
Numerator-denominator evaluaon:
Evaluaon line velocity - numerator 40x5051:007
Evaluaon line velocity - denominator 40x5051:008
Example:
The speed-determining drive is the master of a machine. The master operates with a rotary
measuring s
ystem and a feed constant of [360°/r]. The speed in [°/s] is transmied via the sys-
tem bus to the winder. A single output-end revoluon of the master conveys the material by
194.7787 [mm] per revoluon in the direcon of material ow. This distance corresponds to
the circumference of the feed roll or the measuring wheel. This results in a factor of 1:1.
Relaonship of numerator to the denominator
Evaluaon line velocity - numerator = 194.7787
[mm] (linear feed) 40x5051:007
Evaluaon line velocity - denominator = 360.0000 [°] (congured feed constant of master)
40x5051:008
If necessary, the line speed signal can be negated with a negave value via the parameter
Evaluaon line velocity - numerator. 40x5051:007
0x5021:152
1
0
3
1
0
0x50 :0B 011
0x4001:000
0x5020:020
0x5050:012
0x5051:009
Master velocity in
Actual velocity
Fieldbus
Systembus
Interface switch
Source line velocity
Reference line velocity
Actual line velocity
Fig. 36: Selecon of the source for the line speed
Relevant parameters of other funcons
Address Designaon Default seng Seng range
0x4001 Interface
selecon Fieldbus network [0] Selecon list
0x500B:011 Actual velocity - (Read only)
0x5020:020 Line velocity source External [0] Selecon list
0x5021:152 System bus diagnoscs: Velocity (input value) - (Read only)
0x5051:007 Evaluaon line velocity - numerator 1.0000000000 -2147483648.0000000000 ...
2147483647.0000000000
0x5051:008 Evaluaon line velocity - denominator 1.0000000000 -2147483648.0000000000 ...
2147483647.0000000000
0x5051:009 Actual line velocity x.xxxx mm/s (Read only)