EasyManua.ls Logo

Lenze i950 - Page 100

Lenze i950
496 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Checking the winding direcon
The winder is without material.
How to check the winding direcon:
1.
Enable tension-controlled (open loop) operaon. 40x5050:010 Bit 18 TRUE
2.Set the parameter Winding direcon with line velocity > 0 to TRUE. 0x5051:011
The material will now be unwound when there is a posive line speed signal.
3.Set the parameter Winding direcon with line velocity > 0 to FALSE. 0x5051:011
The material will now be rewound when there is a posive line speed signal.
How to congure the tensile force characterisc:
1.
Set the tensile force setpoint to 300 N. 40x5051:013
2.Set the parameter Gradient of tension characterisc to 75 %. 0x5052:001
The tensile force decreases with increasing diameter from 300 N to 225 N.
The winding direcon check is now complete.
Parameter
Address Name / seng range / [default seng] Info
0x5051:009 Actual line velocity
Read only: x.xxxx mm/s
The parameter is resolved with 4 decimal posions. The parameter has
the unit [mm/s].
0x5051:011 Winding direcon with line velocity > 0
false Rewinder Rewind acve
true Unwinder Unwind acve
0x5051:012 Line velocity reference
0.0000 ... [1000.0000] ... 214748.3647 mm/s
0x5051:013 Min. line velocity
-214748.3648 ... [1.0000] ... 214748.3647 mm/s
Conguring the "Winder Dancer" TA
Con
trol sengs
Dening the winding direcon
100

Table of Contents

Other manuals for Lenze i950

Related product manuals