EasyManua.ls Logo

Lenze i950

Lenze i950
496 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19.2 Safe Emergency Stop (SSE)
The SSE safety funcon has the highest priority. The SSE safety funcon is primarily triggered
fr
om all states, operang modes or safety funcons. Depending on the parameter seng in
0x28A3:0010x28A3:001, the emergency stop funcon acvates one of the funcons:
4Safe Torque O (STO)
4Sa
fe Stop 1 (SS1)
NOTICE
Emergency stop buons must not be overruled by a special operaon.
Otherwise the
funconal safety of the system cannot be guaranteed anymore.
Please observe the notes in the secon
.
Please observe the notes regarding the special operaon (OMS) in the secon
4
Operaon mode selector (OMS). ^ 432
Precondions
The emergency stop buons are connected to the emergency stop funcon.
Details
The
funcon is acvated by the following:
a da
ta telegram with a corresponding content is sent to the inverter via the safety bus.
"OFF state" at a safe input which has been assigned to the funcon by parameterisaon.
Via a safe input, if the corresponding parameter is assigned to the safe input.
Acvaon of the
funcon
A data telegram is sent to the inverter via the safety bus. See chapter "Safe network interfa-
ces". ^ 439
Parameter
Address Name / seng range / [default seng] Info
0x28A1 SSE: Source SD-In
R
ead only
0 Deacvated
1 SD-In1
2 SD-In2
3 SD-In3
4 SD-In4
0x28A2 SSE: Source S-Bus
Read only
0 Deacvated
1 Acvated
0x28A3:001 SSE: SSE: Emergency Stop funcon
R
ead only
0 STO
1 SS1
0x28A4 SSE acve: Output
R
ead only
0 Deacvated
1 SD-Out1 posive logic
2 SD-Out1 negave logic
Safety