6.3.4 Source of monitoring signal
A monitoring signal can be selected for control word 6 and control word 7.
The source for the monitoring signal to be output is selected via the Sour
ce for monitoring
signal parameter. The number of decimal posions transferred depends on the value selected.
•
Selecon for the control word 6: 40x5050:006
•
Selecon for the control word 7: 40x5050:007
The source for the monitoring signal to be output is selected via the Source for monitoring
signal parameter. The number of decimal posions transferred depends on the value selected.
0x5030:006
0x5050:006
(Source monitoring signal 1)
None
Actual motor temperature
Actual motor current
DC bus voltage
Thermal load device
Thermal load motor
Analog input
Actual dancer position
Speed limit master
0x5050:116
(Monitoring signal 1)
Fig. 21: Selecon of digital output
0x5050:007
(Source monitoring signal 2)
None
Actual motor temperature
Actual motor current
DC bus voltage
Thermal load device
Thermal load motor
Analog input
Actual dancer position
Speed limit master
0x5050:117
(Monitoring signal 2)
Fig. 22: Selecon of digital output
Parameter
Address Name / seng range / [default seng] Info
0x5050:006 Display value 1 Signal selecon for monitoring signal 1 for status word 6.
0 None
1 Actual motor temperature
2 Actual motor current
3 DC-bus voltage
4 Device ulisaon
5 Motor ulisaon
6 Analog input 1
7 Actual dancer posion
8 Master speed limit
0x5050:007 Display value 2 Signal selecon for monitoring signal 2 for status word 7.
0 None
1 Actual motor temperature
2 Actual motor current
3 DC-bus voltage
4 Device ulisaon
5 Motor ulisaon Signal selecon for monitoring signal 2 for status word 7.
6 Analog input 1
7 Actual dancer posion
8 Master speed limit
0x5050:116 Display value 1
0 ... [0] ... 4294967295
0x5050:117 Display value 2
0 ... [0] ... 4294967295
Technology applicaon (TA) basic sengs
Dening control sources
Sour
ce of monitoring signal
80