Parameter
Address Name / seng range / [default seng] Info
0x5050:001 Simulaon of control signals
0x00 ... [0x00] ... 0xFF
Bit 0 Enable control signal simulaon TRUE: The
simulaon of the control signals is acvated.
FALSE: The control signals are transmied via the eldbus or the system
bus interface.
Bit 1 Acvate
simulaon of control word 1 TRUE: The simulaon of control word 1 is acvated.
FALSE: The control word is transmied via the eldbus or the system bus
interface.
Bit 2 Acvate
simulaon of control word 2 TRUE: The simulaon of control word 2 is acvated.
FALSE: The control word is transmied via the eldbus or the system bus
interface.
Bit 3 Acvate simulaon of control word 3 TRUE: The simulaon of control word 3 is acvated.
FALSE: The control word is transmied via the eldbus or the system bus
interface.
Bit 4 Acvate simulaon of control word 4 TRUE: The simulaon of control word 4 is acvated.
FALSE: The control word is transmied via the eldbus or the system bus
interface.
Bit 5 Acvate simulaon of control word 5 TRUE: The simulaon of control word 5 is acvated.
FALSE: The control word is transmied via the eldbus or the system bus
interface.
Bit 6 Acvate simulaon of control word 6 TRUE: The simulaon of control word 6 is acvated.
FALSE: The control word is transmied via the eldbus or the system bus
interface.
Bit 7 Acvate simulaon of control word 7 TRUE: The simulaon of control word 7 is acvated.
FALSE: The control word is transmied via the eldbus or the system bus
interface.
0x5050:101 Simulaon of status signals
0x00 ... [0x00] ... 0xFF
Bit 0
Conguring the "Winder Dancer" TA
In
terface
Simulaon of the interface
113