Parameter
Address Name / seng range / [default seng] Info
0x500A:035 Motor mounng
direcon
Seng can only be changed if the inverter is inhibi-
ted.
If the parameter is set to CCW, a posive moon of the machine is inver-
ted so that the direcon of rotaon of the motor becomes negave.
false CW CW : Clockwise rotang motor = posive machine direcon
true CCW CCW : Counter-clockwise rotang motor = negave machine direcon
0x500B:035 Load encoder mounng direcon
Seng can only be changed if the inverter is inhibi-
ted.
The mounng direcon of the addional load encoder is set in this
parameter.
false CW CW : Clockwise rotang motor = posive machine direcon
true CCW CCW : Counter-clockwise rotang motor = negave machine direcon
0x5051:037 Winder speed
Read only: x.xx rev/s
0x5051:050 Manual jog velocity
0.0000 ... [10.0000] ... 214748.3647 mm/s
0x5051:051 Manual jog acceleraon
1.00 ... [1.00] ... 21474836.47 mm/s²
0x5051:052 Manual jog deceleraon
1.00 ... [1.00] ... 21474836.47 mm/s²
0x5051:053 Manual jog jerk
0.00 ... [100.00] ... 21474836.47 mm/s³
0x5051:096 Actual diameter
Read only: x.xxxx mm
The parameter is resolved with 4 decimal posions. The parameter has
the unit [mm].
Conguring the "Winder Dancer" TA
Manual jog of winding sha