9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C00464
312 L EDS94ARNExxxx EN 2.3 - 06/2014
C00464
C00465
C00466
C00467
C00468
C00469
C00512
Parameter | Name:
C00464 | Keypad: Mode
Data type: UNSIGNED_16
Index: 24111
d
= 5E2F
h
From software version V2.0 onwards
Definition of the mode for accessing the attached keypad.
• If both keypad versions (V1.0 and V2.0) are used, the Lenze setting has to be selected.
• If only the new keypad (V2.0) is used, the initialisation time of the keypad can be reduced by changing to mode
2. Furthermore, mode 2 will support larger keypad files in future.
Note: If mode 2 is selected, the V1.0 keypad cannot be operated on the controller!
Selection list (Lenze setting printed in bold) Information
0Mode 1 For keypad V1.0 and V2.0
1 Mode 2 For keypad V2.0 only
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00465 | Keypad: Welcome screen time-out
Data type: UNSIGNED_8
Index: 24110
d
= 5E2E
h
Selection list (Lenze setting printed in bold)
0 Never show welcome screen
55 min
15 15 min
30 30 min
60 60 min
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00466 | Keypad: Default parameters
Data type: UNSIGNED_16
Index: 24109
d
= 5E2D
h
Setting range (min. value | unit | max. value) Lenze setting
0 65535 0
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00467 | Keypad: Default welcome screen
Data type: UNSIGNED_8
Index: 24108
d
= 5E2C
h
Selection list (Lenze setting printed in bold)
0 Main menu
1 Parameter list
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00468 | Service code
Data type: UNSIGNED_8
Index: 24107
d
= 5E2B
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C00469 | Service code
Data type: UNSIGNED_8
Index: 24106
d
= 5E2A
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C00512 | Service code
Data type: UNSIGNED_32
Index: 24063
d
= 5DFF
h
This code is used internally by the device and must not be overwritten by the user!