Page #86 background imageLoading...
Page #86 background image
9400 regenerative power supply module | Parameter setting
Device interface
Monitoring the device utilisation
86 L EDS94ARNExxxx EN 2.3 - 06/2014
4.4 Monitoring the device utilisation
C00064
displays the device utilisation (I x t) over the last 180 seconds in [%].
If the value displayed in C00064
exceeds the warning threshold set in C00123, the error
message "Device utilisation Ixt > C00123" is output and the error response set in
C00604
occurs (default setting: "Warning").
If the value displayed in C00064
exceeds 100 %, the error message "Device utilisation
Ixt > 100 %" is output and the error response "Fault" occurs.
The error can only be reset if the value displayed in C00064
drops to < 95 % again.