EasyManua.ls Logo

Lenze L-force 9400 Series

Lenze L-force 9400 Series
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9400 regenerative power supply module | Parameter setting
Device interface
Monitoring the device utilisation
86 L EDS94ARNExxxx EN 2.3 - 06/2014
4.4 Monitoring the device utilisation
C00064
displays the device utilisation (I x t) over the last 180 seconds in [%].
If the value displayed in C00064
exceeds the warning threshold set in C00123, the error
message "Device utilisation Ixt > C00123" is output and the error response set in
C00604
occurs (default setting: "Warning").
If the value displayed in C00064
exceeds 100 %, the error message "Device utilisation
Ixt > 100 %" is output and the error response "Fault" occurs.
The error can only be reset if the value displayed in C00064
drops to < 95 % again.