9400 regenerative power supply module | Parameter setting
Device interface
Device commands
56 L EDS94ARNExxxx EN 2.3 - 06/2014
4.1.16 Enable controller
The device command C00002
= "42: Enable controller" serves to re-enable an inhibited
regenerative power supply module.
Tip!
This device command can also be activated via the icon in the Toolbar.
Related device commands
Inhibit controller
( 55)
Note!
Please note that the regenerative power supply module will only be enabled if all
sources for controller inhibit are reset!
The sources or trip elements that are active for controller inhibit are displayed
in a bit-coded manner in C00158
.
This device command has no status display in C00003
, i.e. the display remains
unchanged showing the previous device command status.