9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list
272 L EDS94ARNExxxx EN 2.3 - 06/2014
10.2 Parameter list
This chapter describes all parameters of the operating system in numerically ascending
order.
C00002
Note!
The parameter descriptions are based on software version V2.
Parameter | Name:
C00002 | Device commands
Data type: UNSIGNED_32
Index: 24573
d
= 5FFD
h
Device commands
C00003
shows the state of the last executed device command.
•Under C00150
you can query the current state of the device control.
Note:
Before switching off the supply voltage after a device command has been executed, check via the status display in
C00003
that the device command has been executed successfully!
The meaning of the status display in C00003
can be obtained from the subchapter for the corresponding device
command in the "Device commands
" chapter.
Selection list (Lenze setting printed in bold) Information
0 Load Lenze setting Resets parameters to Lenze setting.
Only possible when the controller is inhibited and the
application has been stopped.
1 Load start parameters Loads parameters from the memory module.
Only possible when the controller is inhibited and the
application has been stopped.
2 ENP: Load route data Reads plant data from the electronic filter nameplate.
Only possible when the controller is inhibited and the
application has been stopped.
5 Activate application Activates the application selected under C00005
.
Whether the application is also started, depends on
the auto-start setting selected.
Only possible when the application has been stopped.
7 Save selected application Selects the active application as start application.
11 Save start parameters Saves parameters fail-safe in the memory module.
20 Delete logbook Deletes all logbook entries.
21 Archive log file Exports logbook entries to file.
31 Start application
32 Stop application
33 Reset program Executes a reset.
All variables are reset to their initialisation values.
The situation corresponds to the start of a new
program loaded into the control system (cold start).
34 Delete program Executes a reset (original).
All variables are reset to their initialisation values.
The application program is deleted and the
regenerative power supply module is reset to its
original state.

Table of Contents

Other manuals for Lenze L-force 9400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze L-force 9400 Series and is the answer not in the manual?

Lenze L-force 9400 Series Specifications

General IconGeneral
BrandLenze
ModelL-force 9400 Series
CategoryServo Drives
LanguageEnglish

Related product manuals