EDS94ARNExxxx EN 2.3 - 06/2014 L 87
9400 regenerative power supply module | Parameter setting
Device interface
Display of peak power
4.5 Display of peak power
This function is available from software version V2.0 onwards!
The following parameters display the peak power of the regenerative power supply
module and the corresponding state of the elapsed-hour meter, at which the respective
peak power has been reached:
The display values are stored in the memory module with power failure protection and
are therefore even available after device replacements. After a device replacement,
however, the time reference is updated only after a new peak value has been recorded.
The display values can be reset to zero via the following device commands (C00002
):
–60: Reset max DC power mot.
( 58)
–61: Reset max DC power reg.
( 59)
–62: Reset max. line power reg.
( 60)
Resetting of the display values also sets the corresponding time stamp to the current
state of the elapsed-hour meter (= time of reset).
Parameter Information Lenze setting
Value Unit
C00143/1 Max. DC-power mot. - kW
C00144/1 Time stamp max. DC-power mot. - s
C00143/2 Max. DC-power reg. (+ br. chop.) - kW
C00144/2 Time stamp max. DC-power reg. - s
C00143/3 Max. line power reg. - kW
C00144/3 Time stamp max. line power reg. - s