EDS94ARNExxxx EN 2.3 - 06/2014 L 41
9400 regenerative power supply module | Parameter setting
Device interface
Device commands
4.1.3 Load route data from the ENP
If the Lenze filter connected to the regenerative power supply module is provided with an
electronic nameplate (ENP), at the first switch-on of the regenerative power supply module
all filter data are automatically read out from the electronic nameplate of the filter and
temporarily saved in the regenerative power supply module.
The C00002
= "2: ENP: Load route data" device command can be used to reload the filter
data from the electronic nameplate (ENP) of the filter.
Only possible when the controller is inhibited and the application has been stopped.
For a permanent availability of the filter data, the parameter set must then be
saved.Save start parameters
( 44)
Possible status displays for this device command
Status (C00003) Meaning
165122 Device command in process
131072 Device command executed successfully
131073 General fault

Table of Contents

Other manuals for Lenze L-force 9400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze L-force 9400 Series and is the answer not in the manual?

Lenze L-force 9400 Series Specifications

General IconGeneral
BrandLenze
ModelL-force 9400 Series
CategoryServo Drives
LanguageEnglish

Related product manuals