Page #44 background imageLoading...
Page #44 background image
9400 regenerative power supply module | Parameter setting
Device interface
Device commands
44 L EDS94ARNExxxx EN 2.3 - 06/2014
4.1.6 Save start parameters
Parameter changes in the regenerative power supply module carried out via the
»Engineer« or keypad will get lost after mains switching of the regenerative power supply
module, or after loading another application, unless the settings have been explicitly
saved.
The C00002
= "11: Save start parameters" device command can be used to save the current
parameter settings of the active application with mains failure protection in the memory
module of the regenerative power supply module.
[4-5] "Save start parameters" function
Tip!
The left function key of the keypad can be used to execute this device command if
the function is currently assigned to this key.
* In this example application 1 is the active application
PS
9400
RAM
Firmware Application 1*
PS
Application 3
PS
Application 2
PS
Memory module MM
PS
Application 1*
Note!
The storing process can take a few seconds. Before switching off the supply
voltage after this device command has been executed, check via the status
display in C00003
that the device command has been executed successfully!

Table of Contents

Other manuals for Lenze L-force 9400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze L-force 9400 Series and is the answer not in the manual?

Lenze L-force 9400 Series Specifications

General IconGeneral
BrandLenze
ModelL-force 9400 Series
CategoryServo Drives
LanguageEnglish

Related product manuals