EDS94ARNExxxx EN 2.3 - 06/2014 L 273
9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list
35 Restart program Executes a reset (warm start).
All variables except for the RETAIN variables are reset
to their initialisation values.
The situation corresponds to a power failure or a
switching off and on again of the regenerative power
supply module (warm start) while the program is
running.
36 Reset runtime measurement Runtime measurement
41 Inhibit controller
42 Enable controller
43 Reset error
47 Internal command 47 For Lenze service only
48 Internal command 48 For Lenze service only
60 Reset max DC power mot. From software version V2.0 onwards
Resets the value displayed in C00143/1
to zero.
Display of peak power
61 Reset max DC power reg. From software version V2.0 onwards
Resets the value displayed in C00143/2
to zero.
Display of peak power
62 Reset max line power reg. From software version V2.0 onwards
Resets the value displayed in C00143/3
to zero.
Display of peak power
65 Reset transmitted energy From software version V2.0 onwards
Resets the value displayed in C00145/1
to zero.
Display of transmitted and regenerated energy
66 Reset regenerated energy From software version V2.0 onwards
Resets the value displayed in C00145/2
to zero.
Display of transmitted and regenerated energy
91 CAN on-board: Reset node Reinitialises the "CAN on board" interface.
Required when the baud rate, node address or
identifiers have been changed.
"CAN on board" system bus
92 CAN module: Reset node Reinitialises CANopen interface of the CANopen
communication module.
Required when the baud rate, node address or
identifiers have been changed.
93 CAN on-board: Pred.Connect.Set Sets basic identifier for the "CAN on board" interface
according to the "Predefined Connection Set" (DS301
V4.02).
"CAN on board" system bus
94 CAN module: Pred.Connect.Set Sets basic identifier for the CANopen interface of the
CANopen communication module according to the
"Predefined Connection Set" (DS301 V4.02).
95 CAN on-board: Identify node Identifies the nodes connected to the "CAN on board"
interface.
The result of the CAN bus scan is displayed in C00393
.
"CAN on board" system bus
96 CAN module: Identify node Identifies the nodes connected to the CANopen interface
of the CANopen communication module.
The result of the CAN bus scan is displayed in C13393
(for MXI1) or C14393 (for MXI2).
101 Unbind/bind Ethernet module MXI1 Reinitialises the Ethernet interface of the Ethernet
communication module in the module slot MXI1.
Required when a new IP or gateway address is to be
accepted without mains switching.
Parameter | Name:
C00002 | Device commands
Data type: UNSIGNED_32
Index: 24573
d
= 5FFD
h

Table of Contents

Other manuals for Lenze L-force 9400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze L-force 9400 Series and is the answer not in the manual?

Lenze L-force 9400 Series Specifications

General IconGeneral
BrandLenze
ModelL-force 9400 Series
CategoryServo Drives
LanguageEnglish

Related product manuals