9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C00392
310 L EDS94ARNExxxx EN 2.3 - 06/2014
C00392
C00393
C00394
C00395
C00396
C00397
C00398
C00399
Parameter | Name:
C00392 | CAN emergency delay time
Data type: UNSIGNED_16
Index: 24183
d
= 5E77
h
Minimum time between two successive emergency telegrams.
Setting "0" deactivates the inhibit time check.
The delay time is entered in 1/10 ms. The code automatically rounds the entries down to the preceding full
millisecond.
Mapping of the CANopen object I-1015
(see DS301 V4.02).
"CAN on board" system bus
Setting range (min. value | unit | max. value) Lenze setting
0 65535 0
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00393 | CAN result - bus scan
Data type: UNSIGNED_8
Index: 24182
d
= 5E76
h
Result of CAN bus scanning (see device commands under C00002).
Subcode number 1 ... 128 corresponds to CAN node address 1 ... 128.
"CAN on board" system bus
Display range (min. value | unit | max. value)
0 1
Subcodes Information
C00393/1 Result of CAN bus scanning for CAN node address 1 ...
128
"1" means that a node with the corresponding node
address has been found.
C00393/...
C00393/128
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00394 | Service code
Data type: UNSIGNED_32
Index: 24181
d
= 5E75
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C00395 | Service code
Data type: UNSIGNED_32
Index: 24180
d
= 5E74
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C00396 | Service code
Data type: UNSIGNED_32
Index: 24179
d
= 5E73
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C00397 | Service code
Data type: UNSIGNED_32
Index: 24178
d
= 5E72
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C00398 | Service code
Data type: UNSIGNED_32
Index: 24177
d
= 5E71
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C00399 | Service code
Data type: INTEGER_32
Index: 24176
d
= 5E70
h
This code is used internally by the device and must not be overwritten by the user!

Table of Contents

Other manuals for Lenze L-force 9400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze L-force 9400 Series and is the answer not in the manual?

Lenze L-force 9400 Series Specifications

General IconGeneral
BrandLenze
ModelL-force 9400 Series
CategoryServo Drives
LanguageEnglish

Related product manuals