274 L EDS94ARNExxxx EN 2.3 - 06/2014
102 Unbind/bind Ethernet module MXI2 Reinitialises the Ethernet interface of the Ethernet
communication module in the module slot MXI2.
Required when a new IP or gateway address is to be
accepted without mains switching.
201 Activate parameter set 1 Loads parameter set 1 from the memory module.
Only possible when the controller is inhibited and the
application has been stopped.
202 Activate parameter set 2 Loads parameter set 2 from the memory module.
Only possible when the controller is inhibited and the
application has been stopped.
203 Activate parameter set 3 Loads parameter set 3 from the memory module.
Only possible when the controller is inhibited and the
application has been stopped.
204 Activate parameter set 4 Loads parameter set 4 from the memory module.
Only possible when the controller is inhibited and the
application has been stopped.
301 Archive parameter set 1 Saves the current parameter set as parameter set 1 in the
memory module.
302 Archive parameter set 2 Saves the current parameter set as parameter set 2 in the
memory module.
303 Archive parameter set 3 Saves the current parameter set as parameter set 3 in the
memory module.
304 Archive parameter set 4 Saves the current parameter set as parameter set 4 in the
memory module.
401 Internal command 401 For Lenze service only
730 Internal command 730 For Lenze service only
731 Internal command 731 For Lenze service only
732 Internal command 732 For Lenze service only
733 Internal command 733 For Lenze service only
800 Internal command 800 For Lenze service only
1001 Internal command 1001 For Lenze service only
1020 Internal command 1020 For Lenze service only
1021 Export parameters to file For Lenze service only
1030 Format file system Formats the file system of the memory module.
1040 Restore file system Restores the file system of the memory module (low
level formatting).
The low level formatting of the file system by the user
is only intended for the exceptional case when the
standard formatting is not possible anymore, e.g. due
to damaged internal management information.
10000 Prepare firmware update Sets the regenerative power supply module to the
firmware update mode.
11000 Restart controller Restarts the regenerative power supply module via
parameterisation.