EasyManua.ls Logo

Loop Telecom IP6610 - Ethernet Connection; Line Connections; Table 2-2 RJ45 10;100 M Ethernet Connector Pin Assignment; Table 2-3 E1;RJ48 Connector Pin Assignment

Default Icon
190 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Loop-IP6610 Installation
6
2.5.2 Ethernet Connection
RJ45 10/100M Ethernet connection pin assignments are listed in Table 2-2 below.
Table 2-2 RJ45 10/100M Ethernet Connector Pin Assignment
Pin Number Signal Signal Direction
1 Transmit Data + Output from IP 6610
2 Transmit Data - Output from IP 6610
3 Receive Data + Input to IP 6610
4 No Connection
5 No Connection
6 Receive Data - Input to IP 6610
7 No Connection
8 No Connection
Note: The Ethernet interface supports Auto MDI/MDI-X and will work with either a parallel or a crossover
cable.
2.5.3 Line Connections
Line connections are either via BNC( E1) connectors or RJ48 (E1/DS1) connectors. E1 and DS1 pin
assignments for the RJ48 connector are listed in Tables 2-3 and 2-4, below.
Table 2-3 E1/RJ48 Connector Pin Assignment
Pin Number Signal Signal Direction
1 Receive Ring From E1 Network
2 Receive Tip From E1 Network
3 Unassigned
4 Transmit Ring To E1 Network
5 Transmit Tip To E1 Network
6 Unassigned
7 Shield Ground
8 Shield Ground
Table 2-4 DS1/RJ48 Connector Pin Assignment
Pin Number Signal Signal Direction
1 Receive Ring From DS1 Network*
2 Receive Tip From DS1 Network*
3 Unassigned
4 Transmit Ring To DS1 Network*
5 Transmit Tip To DS1 Network*
6 Unassigned
7 Shield Ground
8 Shield Ground