Chapter 3 Operation
14
Table 3- 10 DTE Alarm Type Table
Alarm Type Alarm Description Threshold
"dcd" Data carrier detect no
"cts" Clear to send no
"dsr" Data set ready no
3.12.2 Reports
The performance and statistics parameters are listed in Tables 3-10 and 3-11, below. Each performance
parameter has 96 sets of registers to record 24-hour history in 15-minute intervals.
Table 3- 11 E1 Statistics Parameter List
Statistics Parameter Description
%AS Available Second
%EFS Error Free Second
%ES Error Second
%BES Bursty Error Second
%SES Severe Error Second
%CSS Controlled Slip Second
Table 3- 12 DS1 Statistics Parameter List
Statistics Parameter Description
%AS Available Second
%EFS Error Free Second
%ES Error Second
%BES Bursty Error Second
%SES Severe Error Second
%CSS Controlled Slip Second
Table 3-11, lists the types of reports available, performance parameters provided by each report, and the
reset commands for each report.
Table 3- 13 Performance Report Options