6-33
7.2 CHECKING AFTER STARTING ENGINE
Precautions shown in this section must be practiced prior to the day’s work, without fail.
Serious injury or death may arise when these inspections are neglected.
Further, refer to the section of “OPERATION 2.1 Checking before Operation” for the checking of
the crane structure.
Whenever any failures are revealed in such inspections, repair them, or contact us or our
agents for services.
7.2.1 VERIFICATION FOR THE ENGINE START AND STOP
• Ensure that the boom and outriggers are in the stow position, entirely.
In case where they are not in those positions, manipulate applicable levers of the Crane to
make them stowed.
Otherwise, the Transmitter operation may cause damages to the Crane or tipping that results
serious injury or death.
• The Crane is inoperable in such event where the LCD screen in the Transmitter shows an error
message or the Monitor display in the Receiver shows an error code.
Without fail, examine the cause of the error and perform appropriate service when any fault is
identified,or contact us or our agents for services.
[1] CHECKING ENGINE START OPERATION
1. Position the Starter Switch of the Crane to ON.
2. Next, push the Power switch of the Transmitter, to power ON.
3. Then turn ON the Main switch of the Receiver.
4. Here, push the Horn button and confirm that the horn toots.
5. Use the Start/Reset button to check that the engine starts
properly.
6. Check whether the indication as “START” appears in the LCD
screen, at that time.
[2] CHECKING ENGINE EMERGENCY STOP OPERATION
1. When the engine is started as in the above [1], try the Stop/EMO
button to confirm that the engine absolutely stops.
2. Here, check whether the indication as “STOP” appears in the
LCD screen.
Further, confirm that the Monitor display in the Receiver shows
the error code, “E1”, at that time.