Magtrol Model DSP7000 Dynamometer ControllerChapter 3 – Installation/Configuration
SETUP
4.a If using an Eddy Current Dynamometer, press SHIFT. The display should appear as follows:
POWER
BRAKE STATUS SET POINT SET POINT PID
TORQUE SPEED USER DISPLAY
TSC1 MAX TORQUE NOMINAL SPEED
XXXX XXXX.X
Figure 3–16 TSC1 Eddy-Current Setup Menu
Press the TORQUE UNITS button and use and buttons and Decrease/Increase dial to
set desired max torque. Press the SCALE P button and use and buttons and Decrease/
Increase dial to set desired nominal speed. Press SHIFT 3 times to complete the initial setup
and return to the main menu.
4.b If using a Powder Brake Dynamometer, press SHIFT. The display should appear as follows:
POWER
BRAKE STATUS SET POINT SET POINT PID
TORQUE SPEED USER DISPLAY
TSC1 MAX TORQUE
XXXX
Figure 3-17 TSC1 Powder Brake Setup Menu
Press the TORQUE UNITS button and use and buttons and Decrease/Increase dial to
set desired max torque. Press SHIFT 3 times to complete the initial setup and return to the
main menu.