82
Magtrol Model DSP7000 Dynamometer ControllerChapter 7 – Computer Controlled Operation
OPERATION
7.4.7 MiSCellaneouS CoMManDS
Command
Code
Channel 1
Command
Code
Channel 2
Function Explanation
FRZ1,# FRZ2,# Freezes the PID loop. Values for # are:
0 = off
1 = freeze PID
I1 I2 Reset Current output to 0.00%
I1,xx.xx I2,xx.xx Sets current output to xx.xx%. The power supply outputs a
xed value of current. Use
any value # between 0 and
99.99%. (99.99% = 1 Amp).
IO1,xx.xx IO2,xx.xx Sets current offset. (sums
xx.xx% to output of DAC)
Values for # range from 0 to
99.99.
SAVE,# SAVE,# Saves present conguration of
unit to non-volatile memory.
Values for # are:
0 = main board
1 = DSP7002 board
2 = I/O Card 1
3 = I/O Card 2
MODE# MODE# Allows the user to swtich from
7000 mode to 6001 mode and
back.
Values for # are:
0 = 7000 mode
1 = 6001 mode
OS,# OS,# Read speed in four decimal
digits.
Values for # are:
1 = Channel 1
2 = Channel 2
OV,# OV,# Reads voltage applied to A/D
channel in mV.
Values for # are:
1 = Channel 1
2 = Channel 2
3 = I/O Card 1 channel 1
4 = I/O Card 1 channel 2
5 = I/O Card 2 channel 1
6 = I/O Card 2 channel 2
TS1 TS2 Enables tare function.
TR1 TR2 Disable tare function.
TMV1,# TMV2,# TM torque reading invert ag Values for # are:
0 = Normal
1 = Invert

Table of Contents