Pellerin Milnor Corporation 111
After a recycle, the OoB detection system evaluates if the amount of imbalance can be offset by
the machine balancing system. If the amount of imbalance is below a certain threshold, the bal-
ancing system balances the load by injecting water in the cylinder ribs opposite the imbalance.
The washer-extractor then attempts to complete the extract step at the programmed speed.
6.1.1.2.1 If the Extract Step is an Intermediate Extract
BNCLUF01.C09 0000185931 E.2 G.5 G.6 4/15/21 11:44 AM Released
The OoB detection process begins when the cylinder reaches drain speed.
1. The OoB detection system compares the amount of imbalance to a fixed threshold value.
• If the imbalance is less than the fixed threshold value, the balancing system balances the
load and the machine completes the extract step at the programmed speed.
• If the imbalance is greater than the fixed threshold value, the machine completes the ex-
tract step at a reduced speed (210 RPMs).
2. The OoB detection system continues to monitor the imbalance until the end of the step.
6.1.1.2.2 If the Extract Step is a Final Extract
BNCLUF01.C10 0000185930 E.2 G.5 G.12 4/15/21 12:03 PM Released
1. The machine performs a preemptive recycle in drain speed.
2. After the recycle, the OoB detection system evaluates whether the amount of imbalance can
be offset by the machine balancing system.
• If the imbalance can be offset, the balancing system balances the load and completes the
extract step at the programmed speed.
• If the imbalance is too large to be offset by the balancing system, the machine performs
up to three recycles.
– If the imbalance falls within the allowed threshold before or by the third recycle, the
balancing system balances the load and the machine completes the extract step at the
programmed speed.
– If the imbalance remains above the maximum allowed threshold value after the third
recycle, the machine completes the extract step at a reduced speed (210 RPMs).
3. The OoB detection system continues to monitor the imbalance until the end of the step.
6.1.1.2.3 If the Excursion Switch Trips
BNCLUF01.C11 0000185929 E.2 G.5 G.7 4/15/21 9:42 AM Released
If the excursion switch trips while the cylinder accelerates to the programmed extract speed, the
following events occur:
1. The machine performs a recycle.
2. After the recycle, the OoB detection system recalculates the amount of imbalance
• If the new imbalance is less than the lowest threshold value, the machine completes the
extract step at the programmed speed.
• If the new amount of imbalance can be offset, the balancing system balances the load and
the machine completes the extract step at the programmed speed.
Supplemental Information