EasyManua.ls Logo

Milnor MilTouch - Table 9 Outputs on 24-Output Board #2

Milnor MilTouch
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
82
Pellerin Milnor Corporation
Table 8 Outputs on 24-Output Board #1 (cont'd.)
Output #
(Board)
Output #
(Display)
Connections on
Board
Function
Description
17 25 1MTA14-10 & 14-16 T'fer Control #1
Used to transfer control
of Staph Guard
®
machines.
18 26 1MTA14-10 & 14-7 T'fer Control Not #1
Used to transfer control
of Staph Guard
®
machines.
19 27 1MTA14-10 & 14-17 T'fer Control #2
Used to transfer control
of Staph Guard
®
machines.
20 28 1MTA14-10 & 14-8 T'fer Control Not #2
Used to transfer control
of Staph Guard
®
machines.
21 29 1MTA14-10 & 14-18
Clean Signal
Actuate to sound the op-
erator signal on clean side
of Staph Guard
®
machines.
22 30 1MTA14-10 & 14-9 Wash Clutch
On multi-motor ma-
chines, this output en-
gages the wash motor to
the cylinder drive.
23 31 1MTA14-10 & 14-19
Spraydown
On divided-cylinder ma-
chines, actuate this output
to activate spraydown
and wet the goods during
loading.
Table 9. Outputs on 24-Output Board #2
Output #
(Board)
Output #
(Display)
Connections on
Board
Function
Description
0 40 2MTA13-1 & 13-11 Chemical 14
Actuate to inject chemical 14.
1 41 2MTA13-2 & 13-12 Chemical 9
Actuate to inject chemical 9.
2 42 2MTA13-3 & 13-13 Chemical 13
Actuate to inject chemical 13.
3 43 2MTA13-4 & 13-14
Chemical
Flush
Actuate to open the flush valve
for chemicals.
4 44 2MTA13-5 & 13-15 Chemical 15
Actuate to inject chemical 15.
5 45 2MTA13-6 & 13-16 Chemical 11
Actuate to inject chemical 11.
6 46 2MTA13-7 & 13-17 ChemSave
Used to interface with chemi-
cal dispenser systems to con-
trol which machines get
chemicals delivered.