34
Pellerin Milnor Corporation
Lower Fill Temperature The 3rd water valve opens only to decrease the bath temperature to
the desired temperature while the machine is filling.
Water Level
Level 1, 2, and 3 Fill to the level that was configured for Level 1, 2, or 3.
User Defined Fill to a level you input using the keypad, for this step only.
Steam
NO Steam Do not use steam in this step to achieve or to restore the bath temperature.
After, Runs After the desired bath level is achieved, run the step timer, and use steam to
achieve and to maintain the bath temperature.
Stops After the desired bath level is achieved, use steam to achieve the bath temperature with
the step timer stopped. Do not use steam to maintain the temperature.
After, Stops After the desired bath level is achieved, use steam to achieve the bath temperature
with the step timer stopped. If necessary, use steam to maintain the temperature.
Early, After, Runs At the lowest safe bath level, use steam to achieve the bath temperature.
Start the step timer when the desired level is achieved. If necessary, use steam to maintain the
temperature.
Early, Stops At the lowest safe bath level, use steam to achieve the bath temperature. Start the
step timer when the desired level and temperature are achieved. Do not use steam to maintain
the temperature.
Early, After, Stops At the lowest safe bath level, use steam to achieve the bath temperature.
Start the step timer when the desired level and temperature are achieved. If necessary, use
steam to maintain the temperature.
Formula Maintenance