36
Pellerin Milnor Corporation
Do Not Drain The drain valve remains closed to keep the bath liquor for the next step. The next
bath step determines how the cylinder rotates.
Stop with Fill The cylinder does not rotate while the machine is filling. The drain valve opens
after a distribution delay.
Stop with Drain The cylinder does not rotate while the machine is draining. The drain valve
opens when the step timer expires.
Stop with Fill and Drain The cylinder does not rotate while the machine is draining. The drain
valve opens when the step timer expires.
RinSave
®
The cylinder rotates according to a specific sequence, described in the following sec-
tion. The drain valve opens 10 to 15 seconds after the step timer expires.
The RinSave
®
Drain Sequence
1. When the bath ends, the cylinder turns clockwise at wash speed for 8 seconds.
2. Before the drain valve opens, the cylinder accelerates to the standard drain speed for 4
seconds.
3. The drain valve opens and the cylinder turns at standard drain speed for a time determined by
the configured machine type.
4. The cylinder accelerates to RinSave
®
speed for the remainder of the drain sequence.
5. If the next step is an extract step, the cylinder accelerates to the programmed speed. If the next
step is a bath step, the cylinder decelerates to a stop.
Reuse Drain
To Sewer Drain this extract step to the sewer.
Reuse Tank Drain this extract step to a reuse tank through a secondary drain valve.
How to End
Stop The operator signal sounds, and the cylinder coasts to a stop.
Reversing The operator signal sounds, and the cylinder reverses for 20 seconds in each direc-
tion with 3 seconds of dwell time between reversals.
Rotating The operator signal sounds, and the cylinder rotates clockwise at wash speed.
Tumble The operator signal sounds, and the cylinder reverses at wash speed.
Stop + Signal The operator signal sounds and the cylinder coasts to a stop. The operator signal
stops sounding after 2 minutes.
Reversing + Signal The operator signal sounds, and the cylinder reverses for 20 seconds in
each direction with 3 seconds of dwell time between reversals. The operator signal stops
sounding after 2 minutes.
Rotating + Signal The operator signal sounds, and the cylinder rotates clockwise at wash
speed. The operator signal stops sounding after 2 minutes.
Tumble + Signal The operator signal sounds, and the cylinder reverses at wash speed. The op-
erator signal stops sounding after 2 minutes.
Formula Maintenance