86
Pellerin Milnor Corporation
Table 11 Outputs on 24-Output Board #4 (WTB+ only) (cont'd.)
Output #
(Board)
Output #
(Display)
Connections on
Board
Function
Description
MilTouch-EX™ models with
OoB detection, this output lim-
its the extract speed based on
the amount of imbalance.
8 112 4MTA13-9 & 13-19
Washer
Clear
This output signals allied (non-
Miltrac™) loading and dis-
charging devices when the
washer is in a safe position and
the devices can freely move
around it.
9 113 4MTA13-10 & 14-1
Deflate Chute
Seal
Deflates the chute seal if all
safety conditions are met.
10 114 4MTA14-11 & 14-2 Start
Loading
Initializes the loading sequence
when the machine receives the
“Allied Start Loading” input
from the allied loading device,
or the load command from the
Miltrac™ system. This output
remains actuated for the dura-
tion of the loading process.
11 115 4MTA14-12 & 14-3 Start
Discharging
Initializes the discharging se-
quence when the machine re-
ceives the “Allied Start
Discharge” input from the al-
lied discharge device, or the
discharge command from the
Miltrac™ system. This output
remains actuated for the dura-
tion of the discharge process.
12 116 4MTA14-4 & 14-13
Tilt Door
Latch
not used
13 117 4MTA14-4 & 14-14
Chute
Unlatch
Retracts all the chute locks.
14 118 4MTA14-10 & 14-5 Sequencer
Load
Allowed
These outputs determine the se-
quence in which groups of ma-
chines will load and discharge
in multi-machine laundries.
15 119 4MTA14-10 & 14-15 Sequencer
Load
Desired
16 120 4MTA14-10 & 14-6
not used
—
17 121 4MTA14-10 & 14-16
not used
—
Troubleshooting