Chapter 3 Adjustment > Adjust Menu>Replace Head
145
[Other required tools]
(1) Damper (x2)
Refer to the maintenance parts list for part numbers.
(2) Maintenance liquid (200 ml bottle) (--- MISSING LINK ---)
(3) Maintenance head washing unit (--- MISSING LINK ---)
l Procedure
1. Select [#Adjust] > [Replace Head] > [Head unit flushing], then press the [ENTER] key.
2. Check the waste ink tank.
The system automatically proceeds to the next step if the waste ink level is below 40% (800 ml).
There is a risk of waste ink leakage if levels exceed 40% (800 ml) of the waste ink tank. Dispose of
the waste ink, and reset the waste ink tank counter.
Check Waste Ink
level: 40% (0.8 L)
3. Select the Head for washing and press the [ENTER] key.
4. Press the [ENTER] key to start discharge.
DischargeShippingLiq
Start [ENT]
Once discharge is complete, the following is displayed.
Head: 1 _ _ _
1. Set the Washing unit
2. Set the Washing Liquid
3. Lock Tubing clamp
5. Assemble a new Damper.
(1) Remove the damper seal rubber holder.
(2) Apply maintenance liquid to the damper seal rubber holder 3 (included).
Use the correct maintenance liquid for the ink in use.
(3) Attach the damper seal rubber holder 3 to the damper.
3