Chapter 3 Adjustment > Adjust Menu>Replace Head
146
6. Attach the assembled damper.
(1) Push in the Damper until it engages with the claws.
Be careful to avoid catching the Head cable.
7. Apply maintenance liquid to the seal rubber (inside the double damper FIT) on the maintenance head
washing unit.
Use the correct maintenance liquid for the ink in use.
8. Attach the maintenance head washing unit to the Damper.
Push in until the claws engage. Improper attachment may result in leaking maintenance solution.
9. Clamp the tube on the maintenance head washing unit using a tube cock and press the [ENTER] key.
Creates a vacuum to even out flow rate differences between each route.
ClampingClamping
10. Push the maintenance head washing unit on to the maintenance liquid bottle.
Be careful to avoid tipping over the maintenance liquid bottle. If maintenance liquid gets
into the machine, malfunctions, electric shock, or fire may result.