Chapter 4 Testing > Test Menu
151
Item Purpose Overview Ref.
HEAD2: Head heater 2
CHECK INK IC To check for Ink IC chip
contact defects, etc.
Error: [IC=1 ERR=1] is displayed. -
CARTRIDGE
VALVE
To check the cartridge valve
operation
Press the [FUNCTION] key to toggle
between OPEN and CLOSE.
-
Maint.Cartridge To check the operation of the
maintenance liquid cartridge
slot
Cartridge detection sensor and ink-end
sensor check
Valve operation check
Drip prevention shutter and shutter
sensor operation check
-
AGING To test durability
When communication
problems are suspected
between PCBs
This is used to check the continuous
operation of the motors and units.
PCB communication test: This is used
to check communication between the
main PCB and the other PCBs.
P. 155
Check Encoder If the "2.1.4 150LPI Encoder
PCB"(P. 39) was replaced
If "3.1.6 Encoder Sensor
Height Adjustment"(P. 119)
was performed.
Periodic check item
This is used to check the difference
between the Y drive motor encoder
value and the linear encoder scale
coordinate value, and check the
position of the encoder PCB.
P. 157
EVENT LOG Not currently implemented
(used for development)
--- -
CHECK
MESSAGE
To check error or other
messages
--- -
H/W Not currently implemented
(used for development)
--- -
Paper Sensor If an abnormality is detected
in media width detection
@@@: Sensor value read at SLOP-
ON
$$$: Sensor value read at SLOP-OFF
***: Difference between @@@ and $$
$
Sensor readings are refreshed
periodically (every 150 ms).
-
Action Test To check the operation of
moving parts.
Periodic check item
Vacuum: LOW/MID/HIGH/OFF
Cutter: ON/OFF
Take-up Motor: ON/OFF
Ceiling Fan: ON/OFF
LED Pointer: ON/OFF
-
LED To check the LED operation POWER LED: ON/OFF -
Skew Check To check media meandering Specify the feed distance and execute.
Feed distance: 1 m to 10 m (in 1m
increments)
-
VOLTAGE
CHECK
To check the DC power
supply voltage (AD converter
circuit value)
DC power supply name: Design value [V]
V CORE (CPU core voltage): 1.331
12V (Internal circuit operation): 12
V1 (Motor drive, head drive, etc.): 48
5V (Internal circuit operation): 5
3.3VB (Circuit operation in sleep): 3.3
-