Chapter 4 Testing > Test Menu
152
Item Purpose Overview Ref.
3.3V (Internal circuit operation): 3.3
2.5V (Internal circuit operation): 2.5
1.8Vmem (Internal circuit operation):
1.8
1.2V (Low-voltage circuit operation):
1.2
STVpow (Internal circuit operation): 48
ST24V (Internal circuit operation): 24
ST24VA (Internal circuit operation): 24
SL1.2V (Low-voltage circuit operation):
1.2
SL2.5V (Internal circuit operation): 2.5
SL3.3V (Internal circuit operation): 3.3
SL5V (Internal circuit operation): 5
SL48V (Internal circuit operation): 48
SL24V (Internal circuit operation): 24
SL1.8V (Low-voltage circuit operation):
1.8
NCU To check the NCU sensor
sensitivity
If the "2.2.1 NCU"(P. 48) was
replaced
Sensor Chk: This is used to check the
NCU (clogging detection unit) sensor
sensitivity.
Level Adj: Not currently implemented
(used for development)
Nzl Check: Not currently implemented
(used for development)
Nzl Chk Easing: Not currently
implemented (used for development)
Parameter: Not currently implemented
(used for development)
Parameter 2: Not currently
implemented (used for development)
P. 159
BITMAP To check bitmap (font) data
stored in the machine
--- -
SD Card Not currently implemented
(used for manufacturing)
--- -
Valve Test To leave valve open Ink Valve: ON/OFF
DAS sensor To check the DAS sensor
sensitivity
Move the DAS sensor onto white
media and press the [ENTER] key to
confirm that the value is 600 or more.
If it is not more than 600, clean the
DAS sensor.
-