Using CGP01
1 Unravel the lowering rope to be tangle-free.
2 One-by-one, pull back each quick-release cable
retainer (A) threading the cable (B) through as
you go.
3 Connect cable (B) to the crawler.
4 Using the Lowering Rope (see page 43) lower
the crawler into the chamber and
drive into the start position.
5 Lower the guide pulley down the
cable and position into the
invert of the pipe.
6 Tie-o the rope (C)
to secure into
place.
Using CGP01 Cable Guide Pulley
A
C
B
A
A
A
B
136
Version LMinicam Proteus