Instructions for Pressurising the CAM026/26L
1 Connect the PROTEUS
inspection system and apply power.
2
Unscrew the pressure valve protection cap (B) and screw on the pres
sure valve connection adaptor (A).
3 Set the pressure regulator for the CO
2
or Nitrogen to 5 PSI.
4 Ensure the crawler pressure is within the acceptable range by
checking the pressure gauge on the control unit. An example is shown
below. Refer to the CCU section of this manual on specic instructions
on how to access the pressure gauges.
5 Remove the pressure valve connection adaptor
(A)
.
6 Ret the pressure valve protection cap
(B)
.
Image shows an example of the control unit camera pressure
gauge:
B
A
41
Version L Minicam Proteus