EasyManuals Logo

Miranda Kaleido-X User Manual

Default Icon
461 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #150 background imageLoading...
Page #150 background image
142
Configuring Alarms
Configuring Alarm Thresholds
4 In the Properties tab, set the relevant values under Calibration.
Video Calibrations
Black detection
threshold
Set the level (in IRE or mV) below which the signal will be considered
to be black. By default the threshold is set at 8 IRE.
Freeze sensitivity Freeze detection is done by comparing successive frames. Noise in
the signal could disrupt this process, so filtering is added to remove it.
Adjust the sensitivity according to the signal being monitored, on a
range of 0 (for a noisy signal) to 16 (for a clean signal). By default the
sensitivity is set at 8, and the alarm will be triggered after at least 15
seconds of continuous freeze. Once the alarm is triggered it will only
be released if no other freeze condition is detected over the period
determined by the Clear duration parameter (by default, there is no
delay), to avoid unwanted alarm flickering that could be caused by
glitches on the signal.
Note that when setting the Clear duration parameter to any value
other than 0, it may happen that the freeze alarm will only be released
after a long time (longer than the value of the period determined by
the Clear duration parameter) if the video has short-duration freezes
during this period.
SD/HD detection
zone
Determine the video window area to be monitored for Freeze and
Black detection. Two detection zones can be configured: one for SD
signals, one for HD signals.
Luma too high
detection
threshold
Set the level (in IRE or mV) above which Luma too high will be
reported. By default the threshold is set at 100 IRE.
Audio Calibrations
Silence
left/right/center
Select the level (in dB or dBFS for digital audio sources, in dB or dBu
for analog audio sources) below which the audio signal will be
considered silenced. The default value is –55
dBFS, on a range of -63
to 0.

Table of Contents

Other manuals for Miranda Kaleido-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Miranda Kaleido-X and is the answer not in the manual?

Miranda Kaleido-X Specifications

General IconGeneral
BrandMiranda
ModelKaleido-X
CategorySoftware
LanguageEnglish

Related product manuals