544
32 TABLE OPERATION
32.2 Operations of Control Method
Precautions
This table cannot be specified for continuous operation. When a table with this control method is executed in continuous
operation, the operation is decelerated to a stop.
When the specification method for the interpolation speed is [Reference-axis speed], set the axis with the longer positioning
address as the reference axis. If the axis with the shorter positioning address is set as the reference axis, the speed of the
longer axis may exceed the maximum speed and interpolation operation cannot be performed properly.
When such as forward limit or reverse limit, is detected in either of the reference axis or counterpart axis during
interpolation operation, both the axes are decelerated to a stop.
Do not change the value of operand 4.
This function is not intended for purposes where high precision path is required because each axis is only started
simultaneously.
Using the following or similar set values, in particular, may lead to a larger difference in stop time between each axis. Even
when there is a difference in stop time, operation stops at the correct position.
1. When there is a large difference in transfer distance between the reference axis and counterpart axis
2. When the speed of the reference axis or counterpart axis is equal to or lower than the bias speed or exceeds the
maximum speed
3. When the speeds of the reference axis and counterpart axis are extremely slow
4. When an extremely long acceleration time or deceleration time is set
If interpolation operation is aborted, the stop position of each axis may be off the straight line.
Related devices
Special relays
•CPU module
FX5 dedicated FX3 compatible Name High
Speed I/O
Parameter
R/W Reference
Axis 1 Axis 2 Axis 3 Axis 4 Axis 1 Axis 2 Axis 3 Axis 4
SM8029 Instruction execution
complete flag
R Page 417
SM8329 Instruction execution
abnormal end flag
R
SM5500 SM5501 SM5502 SM5503 SM8348 SM8358 SM8368 SM8378 Positioning instruction
activation
R Page 415
SM5516 SM5517 SM5518 SM5519 SM8340 SM8350 SM8360 SM8370 Pulse output monitor R Page 415
SM5532 SM5533 SM5534 SM5535 Positioning error
occurrence
R/W Page 416
SM5628 SM5629 SM5630 SM5631 Pulse output stop
command
R/W Page 396
SM5644 SM5645 SM5646 SM5647 Pulse decelerate and stop
command
R/W Page 397
SM5660 SM5661 SM5662 SM5663 Forward limit R/W Page 398
SM5676 SM5677 SM5678 SM5679 Reverse limit R/W Page 399
SM5772 SM5773 SM5774 SM5775 Rotation direction setting R/W Page 384
SM5916 SM5917 SM5918 SM5919 Positioning table data
initialization disable
R/W Page 414
R: Read only, R/W: Read/write, : Supported, : Not supported