6. Operation Panel Switch Functions
6.5 Dry Run
II - 20
6.5 Dry Run
(1) When the DRY RUN switch is turned on, the feedrate set by using the MANUAL FEED RATE switch
takes precedence over the programmed feedrate (F).
6.6 Manual Override
(1) When the MANUAL OVERRIDE switch is turned on, the override value set by using the FEED
OVERRIDE switch takes precedence over the value set by using the MANUAL FEED RATE switch.
(2) The override value also takes precedence over the dry run during automatic operation.
(3) Manual override becomes effective immediately when the switch is turned on.
6.7 Override Cancel
(1) When the OVERRIDE CANCEL switch is turned on, the programmed F command value takes
precedence over the override value set by using the FEED RATE OVERRIDE switch.
(2) It is not effective for manual override.
6.8 Optional Stop
(1) If M01 is programmed, the machine automatically stops by turning on the OPTIONAL STOP switch.
When the switch is off, M01 is ignored and the machine does not stop.
(Note)
Some processes within the user-PLC are required.
(2) The machine stops after the M01 block is executed.