1. Setting and Display Unit
1.2 Screen Operation of GOT
I - 3
When NC monitor function cannot work, NC data will not be displayed.
Touch the screen to return to the Utility screen.
List of error messages
(If more than one error are occurring at the same time, the error with higher priority is displayed.)
Priority Error message Remedy
High
E71 communication driver is
not installed. (NC monitor)
Install E71 communication
driver.
Middle
Monitor data not found.
(NC monitor)
Download the NC screen data
(special module screen).
Low
The IP address of NC to
monitor is not set up.
(NC monitor)
Set the IP address by the
drawing S/W (Ethernet
setting), and download the
monitor data.
When a communication error occurs during monitoring, the error disappears at recovery of
communication.
Communication error
In the message display area, the alarm or warning message that has the highest priority among the
alarms currently occurs under the current part system.
Message Details of message Remedy
Communication
error
An error has occurred in the
communication with the NC.
•
Check the connection between the NC
and GOT.
(Cable connection, noise, etc.)
•
Check the NC and GOT network
settings.
KEY
OPERATION
INVALID
The NC-dedicated display unit or
display unit other than touch
panel is connected, and key
inputs from the menu section or
keyboard section are invalid.
Inputs from the display unit other
than touch panel are valid in this
case.
The key inputs become valid by following
operations.
•
Disconnect the NC-dedicated display
unit.
•
Press the OPERATE menu.
When some error occurs with the communication with NC, a dialogue box will appear.
Refer to the appendix written later for details of the other alarms or messages.